1.ADC:
Siproin Microelectronics provides high-precision analog-to-digital conversion circuits for power monitoring and smart meters.
1.1 Σ-Δ ADC
NO |
Model |
Channel |
SPS |
Bit |
Work |
Vcc |
Input(V) |
Interface |
Package |
P2P |
Input Model |
1 |
SSP1120 |
4 |
2k |
16 |
2.6mW |
2.3~5.5 |
±Vref/PGA |
SPI |
TSSOP16 |
ADS1120 |
Single-ended/Differential |
2 |
SSP1220 |
4 |
2k |
24 |
2.6mW |
2.3~5.5 |
±Vref/PGA |
SPI |
TSSOP16 |
ADS1220 |
Single-ended/Differential |
1.2 SAR ADC
NO |
Model |
Channel |
SPS |
Bit |
Operating voltage
|
Analog Input(V) |
INL(LSB) |
DNL(LSB) |
SNR(dB) |
SFDR(dB) |
Interface |
Package |
Input Model |
1 |
SSP1680 |
1 |
1M |
16 |
2.5 |
-½Vref~½Vref,0~Vref |
±2 |
±0.8 |
86 |
103 |
SPI |
DFN10、MSOP10 |
Single-ended/Differential |
2 |
SSP1682 |
4 |
250K |
16 |
5 |
-10~10,-5~5 |
±2 |
±0.8 |
87.5 |
103 |
SPI |
MSOP10 |
Single-ended/Differential |
3 |
SSP1606 |
8 |
200K |
16 |
5 |
-10~10,-5~5 |
±1.0 |
±0.8 |
87.5 |
105 |
Parallel/SPI |
QFP64 |
Single-ended/Differential |
4 |
SSP1616 |
16 |
1M |
16 |
2.5,5 |
-10~10,-5~5,-2.5~2.5 |
±2 |
±1 |
89 |
105 |
Parallel/ SPI |
QFP80 |
Single-ended/Differential |
Application:
-
Smart hmeter,intelligent water meter, intelligent gas meter,intelligent heat meter
-
Power monitoring
2.Electric energy metering: >>>>>>TOP
Series high precision electric power measurement integrated circuit, integrated Sigma-Delta ADC, digital signal processing and other analog circuit modules, according to different models can process active power, current and voltage effective value, can provide pulse output or SPI/UART interface.
No |
Model |
Operating voltage |
Power Consumption |
ADC channel |
Feature |
Output model |
Package |
Clock |
Dynamic Range |
1 |
SSP1855 |
5V |
15mW |
2 |
Single phase high precision electricity meter |
Pulse |
SSOP24 |
3.5795MHz |
500:1 0.1% |
2 |
SSP1852 |
5V |
30mW |
6 |
Three - phase high - precision electricity meter |
Pulse |
SOP24 |
10MHz |
500:1 0.1% |
3 |
SSP1837 |
3.3V |
6mW |
6 |
Single - phase multi - function smart socket |
2 Pulse |
SOP8 |
Build-in Clock |
2500:1 1% |
4 |
SSP1839 |
3.3V |
10mW |
6 |
Calibration - free single - phase meter |
Uart/Spi |
SSOP20/SOP16 |
Bulid-in Clock |
2500:1 1% |
5 |
SSP1840 |
3.3V |
8mW |
6 |
Calibration - free single - phase meter |
Uart/Spi |
TSSOP14 |
Build-in Clock |
2500:1 1% |
6 |
SSP1842 |
3.3V |
8mW |
6 |
Calibration - free single - phase meter |
Uart/Spi |
SSOP10 |
Build-in Clock |
2500:1 1% |
Application:
-
Electric meter
-
Industrial meter
-
Intelligent power management
-
Intelligent electrical outlet
-
Charging pile
3.High precision time measurement (TDC) circuit: >>>>>>TOP
High precision time measurement (TDC) circuit integrates high-speed pulse generator, temperature test and clock control, analog comparator, analog switch, Schmidt trigger and other devices.The first wave detection function greatly improves the anti-interference ability and abnormal detection ability, and the programmable offset of the internal comparator can improve the sampling accuracy.Its powerful measurement and calibration capabilities and simple command system make it especially suitable for ultrasonic flow measurement and heat measurement.
No |
Model |
Operating voltage |
Quiescent current |
Time accuracy |
Feature |
Package |
1 |
SSP1922 |
2.5V-3.6V |
<1.5uA |
15ps |
High precision time measurement (TDC) circuit |
QFN32/LQFP32 |
2 |
SSP1930 |
2.5V-3.6V |
<1.5uA |
15ps |
High precision time measurement (TDC) circuit |
QFN32/LQFP32 |
Application:
-
Ultrasonic water meter
-
ultrasonic measurement
4.Leakage protection: >>>>>>TOP
Leakage protection device is A high-performance leakage protection application-specific integrated circuit. It contains a regulated power supply, an amplifier circuit, a comparison circuit, an intelligent delay circuit, a self-recovery control circuit, a latching controller and a SCR drive circuit. There are unhooked coil, varistor, regulator diode, diode, resistor, capacitor and other components.
No. |
Model |
Feature |
Turn on voltage or current |
Operating voltage |
Output current |
Delay times |
Output times |
1 |
SSP54123 |
Type AC special circuit for leakage protection |
6.1mV |
12V |
250uA |
|
5ms |
2 |
SSP54123A |
Type A special circuit for leakage protection |
5mV rms |
4.8v |
2mA |
>10-100ms |
28ms |